CHAPTER 4: INSTALLATION AND WIRINGPage 4 - 1
The inner I/O circuitry of the AFC1150 uses opto-couplers for circuit isolation, as shown infigure 4.5.1-B.Fig. 4.5.1-BCHAPTER 4: INSTALLATIO
Output when the speed changes from slow speed tohigh speed during speed change control mode. Thissignal will be deactivated either by a reset
4.5.2 Timing ChartFig. 4.5.2P Start signal must be held on for duration desired.P Reset signal must be input to reset from abnormal to read
4.5.3 Programmable Logic Controller (PLC)All AFC1150 inputs and outputs are active true low. All interface devices must accommodateactive t
4.6 Jumper Set-UpNOTE: These jumpers are set-up correctly at the factory.TOPJumper location, left side of axis unit. Figure 4.6 assumes cov
This set-up must not be changed.Fig. 4.6.24.6.3 JP1 Set-UpSet-up the jumpers for tool model and servo type.LHLH DRT-302M3-S/OLHLH DRT-202M3
* Standard offset tools utilize the single offset design. The double offset tool is a design similar to thatused in FEC INC. standard F
4.7 tool connectionw Connect the encoder cable and themotor cable to the correspondingnumbered tool. Ensure that the cabletag numbers match
INTENTIONALLY LEFT BLANKCHAPTER 4: INSTALLATION AND WIRINGPage 4 - 18
4.1 Controller 4.1.1 Size and Dimensions.(10.6") 270 mmDepth(11.2") 285 mmHeight(3.7") 93 mmWidth 4.2 kgWeigh
Mounting Location Layout ExampleFig. 4.1.2-BFigure 4.1.2-B provides reference for the layout of the AFC1150 controllers. The units maybe moun
4.2 ToolTool dimensions and mounting specifications are critical in determining the design of thepowerhead that will house the tool assemblie
FIG. 4-2-2 Straight ToolNumbers shown in brackets are in inches. All others shown in millimeters as the standard. 525.513255202.520340405.544
4.3 Wiring DiagramFig. 4.3This reference drawing is intended to provide only a basic layout of the interconnection of thesystem. Circuit pro
4.4 Power Requirements and ConnectionIMPORTANT!!DO NOT CONNECT POWER SOURCE UNTIL THE POWER UP CHECKLIST HASBEEN COMPLETED!REFER TO CHAPTER 5
4.4.1 Calculating Circuit Protection.4 KVA 2.5 SPINDLES 200DRT-302M3-S/O .4 KVA 2.5 SPINDLES 200DRT-202M3-S/O .4 KVA 2.5 SPIND
4.5 Control Signal WiringAll AFC1150 inputs and outputs are active true low. All interface devices must accommodateactive true low logic for